surge protective device
1. Could be replaced for the module not need power cut.
2. Maximum currrent of endure the surge stroke 20kA(8/20μs).
3. Time of response<25ns.
4. The color of visible window shows operating status,green means normal,red means abnormal.
* LY1-D series Surge Protective Device SPD is suitable for TN-S. TN-C-S. TT. IT etc.power supply system of AC 50/60Hz,≤380V,installed on the joint of LPZ1 or LPZ2 and LPZ3,it 's designed according to IEC61643-1. GB18802.1,it adopts 35mm standard rail,there is a failure release mounted on the module of Surge Protective Device.When the SPD fails in breakdown for over-heat and over-current,the failure release will help electric device separate from the power system and give the indication signal,green means normal,red means abnormal,it 's also could be replaced for the module when has operating voltage.
*. It's suitable for D grade surge protection,LY1-D series Surge Protective Device according to GB188021.1-2002, installed on the joint of LPZ1 or LPZ2 and LPZ3,usually installed in household distribution boards,computer equipment,information equipment,electronic equip ment and in the socket box in front of control equipment or near the control equipment.
*.Notice:When you order our goods,please write the model and quantity carefully.For example:LY1-D20/2-275,100 pieces.
Technical Parameters | Model | LY1-D | |||
Rated Operating Voltage Un(V~) |
220V |
380V |
220V |
380V | |
Maximum Continuous Operating Voltage Uc(V~) |
275V |
385V |
320V |
385V | |
Voltage Protection Level Up(V~)kV | ≤0.7 | ≤1.0 | ≤1.2 | ≤1.5 | |
Nominal Discharge Current In(8/μ20μs)kA |
5 |
10 | |||
Maximum Discharge Current Imax(8/μ20μs)kA | 10 | 20 | |||
Response Time ns | <25 | ||||
Test Standard | GB18802. IEC61643-1 | ||||
L/N(mm2) The Cross Section of L/N Line | 6 | ||||
E(mm2) The Cross Section of PE Line | 16 | ||||
Fuse or Switch(A) | 10A. 16A | 16A. 25A | |||
Operating Environment℃ | -40℃~+85℃ | ||||
Relative Humidity(25℃) | ≤95% | ||||
Installation | Standard Rail 35mm | ||||
Material of Outer Covering | Fiber glass reinforced plastic |
SPD Type 2 according to EN 61643-11
SPD Class II according to IEC 61643-1
Classification C according to E DIN VDE 0675-6
- High discharge capacity thanks to powerful zinc oxide varistors / spark gaps
- Low protection level, quick response
- Reliable control thanks to Thermo Dynamic Control disconnector with dual monitoring
- Fault indication by red mark in the inspection window
- Slim design (modular construction) according to DIN 43880
- Multifunctional terminals for connecting conductors and busbars
- Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings
- Complete prewired unit for common system configurations, consisting of a base part and plug-in protection modules
- Plug-in arrester with dynamic separating device
Technical parameters
|
LY1-C40 |
|||
SPD to EN 61643-II |
Type 2 |
|||
SPD to IEC 61643-I |
Class II |
|||
SPD to VDE 0675-6 |
Class C |
|||
Max. continuous voltage Uc |
275 V |
320 V |
385 V |
440 V |
Nominal discharge current (8/20μs) In |
20 kA |
|||
Max. discharge current (8/20μs) Imax |
40 kA |
|||
Voltage protection level Up |
≤ 1.3kV |
≤ 1.5kV |
≤ 1.8kV |
≤ 2.0kV |
Response time tA |
≤ 25 ns |
|||
Max. back-up fuse |
125 A gl/gG |
|||
Short-circuit withstand current |
25kA/50Hz |
|||
Operating temperature range TU |
-40℃…+80℃ |
|||
Cross-sectional area (min.) |
1.5 mm2 solid / flexible |
|||
Cross-sectional area (max.) |
35 mm2 stranded / 25 mm2 flexible |
|||
Mounting on |
35 mm DIN rail acc. To EN 60715 |
|||
Degree of protection |
IP 20 |
|||
Housing material |
Thermoplastic; extinguishing degree UL 94 V-0 |
|||
Remote signaling contact (floating switch) |
Yes (optional accessory) |
|||
Switch capacity |
AC: 250V/0.5A; 125V/3 A |
|||
Cross-sectional area for remote signaling terminals |
Max. 1.5 mm2 solid / flexible |
Order information (Let’s take 385V as example)
Type |
Description |
LY1-C40/1-385 |
Class C, Imax: 40kA, 1 pole, 385V, Surge Protection Device for TN-S, TN-C, IT systems |
LY1-C40/2-385 |
Class C, Imax: 40kA, 2 pole, 385V, Surge Protection Device for TN-S systems (Single-phase) |
LY1-C40/3-385 |
Class C, Imax: 40kA, 3 pole, 385V, Surge Protection Device for TN-C systems (Three-phase) |
LY1-C40/4-385 |
Class C, Imax: 40kA, 4 pole, 385V, Surge Protection Device for TN-S systems (Three-phase) |
Other voltage available: 275V, 320V, 440V
Technical parameters
Maximum continuous operating voltage
|
Uc
|
V
|
320
|
Requirement class to EN 61643-11
|
|
Type 1+2
|
|
Requirement class to IEC 61643-1
|
|
Class I+II
|
|
Requirement class to VDE 0675 part 6
|
|
B+C
|
|
LPZ
|
|
0--2
|
|
Pulsed current (10/350) (L-N)
|
Iimp
|
kA
|
7
|
Pulsed current (10/350) (N-PE)
|
Iimp
|
kA
|
/
|
Nominal discharge surge current (8/20) (L-N)
|
In
|
kA
|
30
|
Nominal discharge surge current (8/20) (N-PE)
|
In
|
kA
|
/
|
Maximum discharge surge current
|
Imax
|
kA
|
50
|
Voltage protection level
|
Up
|
kV
|
<1.8
|
Response time
|
tA
|
ns
|
<25
|
Maximum back-up fuse
|
A
|
160
|
|
Temperature range
|
℃
|
-40~+85
|
|
Protection rating
|
|
IP 20
|
|
Division unit TE (18mm)
|
|
4
|
|
Connection cross-section, rigid
|
mm2
|
2.5~35
|
|
Connection cross-section, multi-wire
|
mm2
|
2.5~35
|
|
Connection cross-section, flexible
|
mm2
|
2.5~35
|
Type
|
Description
|
V25-B+C/1-320
|
Class C, Imax: 40kA, 1 pole, 320V, Surge arrester for TN-S, TN-C, IT systems
|
V25-B+C/2-320
|
Class C, Imax: 40kA, 2 pole, 320V, Surge arrester for TN-S systems (Single-phase)
|
V25-B+C/3-320
|
Class C, Imax: 40kA, 3 pole, 320V, Surge arrester for TN-C systems (Three-phase)
|
V25-B+C/4-320
|
Class C, Imax: 40kA, 4 pole, 320V, Surge arrester for TN-S systems (Three-phase)
|
V25-B+C/1+FS-320
|
Class C, Imax: 40kA, 1 pole, FS: floating switch, 320V, Surge arrester for TN-S, TN-C, IT systems
|
V25-B+C/2+FS-320
|
Class C, Imax: 40kA, 2 pole, FS: floating switch, 320V, Surge arrester for TN-S systems (Single-phase)
|
V25-B+C/3+FS-320
|
Class C, Imax: 40kA, 3 pole, FS: floating switch, 320V, Surge arrester for TN-C systems (Three-phase)
|
V25-B+C/4+FS-320
|
Class C, Imax: 40kA, 4 pole, FS: floating switch, 320V, Surge arrester for TN-S systems (Three-phase)
|